VARIABLE TUMBLE SHUTTER VALVE ACTUATOR INSPECTION [MZR 1.6]
id0113f4803100
Operation inspection
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [MZR 1.6].)
2. Remove the variable tumble shutter valve actuator. (See VARIABLE TUMBLE SHUTTER VALVE ACTUATOR REMOVAL/INSTALLATION [MZR 1.6].)
3. Connect the battery positive voltage to terminal A or B, and verify that the gear moves.
|
Terminal |
Gear rotation direction |
|
---|---|---|
A |
B |
|
B+
|
Ground
|
Clockwise
|
Ground
|
B+
|
Counterclockwise
|