CHECK VALVE INSPECTION [MZR 1.6]


id011607189900

1.  Remove the check valve. (See CHECK VALVE REMOVAL/INSTALLATION [MZR 1.6].)

2.  Verify that there is no airflow when positive pressure is applied to port A.

ac5wzw00001377

•  If there is airflow, replace the check valve. (See CHECK VALVE REMOVAL/INSTALLATION [MZR 1.6].)

3.  Verify that there is no airflow when negative pressure is applied to port A.

•  If there is no airflow, replace the check valve. (See CHECK VALVE REMOVAL/INSTALLATION [MZR 1.6].)