LP-EGR CONTROL VALVE POSITION SENSOR INSPECTION [SKYACTIV-D 1.5]
id0140q2497700
Voltage Inspection
1. Switch the ignition ON (engine off).
2. Measure the voltage at the LP-EGR control valve terminal B.
|
3. Connect the M-MDS to the DLC-2.
4. Access the PID/DATA monitor item LP_EGR_ACT and simulation item LPEGR_DSD using the M-MDS. (See ON-BOARD DIAGNOSTIC TEST [SKYACTIV-D 1.5].)
5. Verify that the LP_EGR_ACT monitor value conforms to the LPEGR_DSD monitor value when the simulation item LPEGR_DSD is set from 0 % to 80 %.
Specification (Reference)
|