EGR VALVE POSITION SENSOR INSPECTION [SKYACTIV-D 2.2]
id0140z7807600
Voltage Inspection
1. Switch the ignition ON (engine off).
2. Measure the voltage at the EGR valve/EGR valve position sensor terminal D.
|
3. Connect the M-MDS to the DLC-2.
4. Start the engine.
5. Access the PID/DATA monitor item EGRP_ACT and simulation item EGRP using the M-MDS. (See ON-BOARD DIAGNOSTIC TEST [SKYACTIV-D 2.2].)
6. Verify that the EGRP_ACT monitor value conforms to the EGRP monitor value when the simulation item EGRP is set from 0 % to 80 %.