EGR COOLER BYPASS VALVE POSITION SENSOR INSPECTION [SKYACTIV-D 2.2]
id0140z7825000
Voltage Inspection
1. Switch the ignition ON (engine off).
2. Measure the voltage at the EGR cooler bypass valve/EGR cooler bypass valve position sensor terminal F.
|
3. Connect the M-MDS to the DLC-2.
4. Start the engine.
5. Access the PID/DATA monitor item EGR_C_BP_ACT and simulation item EGR_C_BP using the M-MDS. (See ON-BOARD DIAGNOSTIC TEST [SKYACTIV-D 2.2].)
6. Verify that the EGR_C_BP_ACT monitor value conforms to the EGR_C_BP monitor value when the simulation item EGR_C_BP is set from 0 % to 90 %.
Specification (Reference)
|