PID/DATA MONITOR INSPECTION [i-ELOOP]
id130201000500
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
3. Select the applicable PID from the PID table.
4. Verify the PID data according to the directions on the screen.
Item |
Unit/Condition |
description |
Condition/Specification (Reference) |
---|---|---|---|
BYPS_COUNT
|
—
|
Count of Bypass Relay actuation
|
• Displays operation amount of the bypass relay.
|
BYPS_RLY_STAT1
|
Low/High
|
State of Bypass Relay Signal 1
|
• Displays the bypass relay signal status.
|
BYPS_RLY_STAT2
|
Low/High
|
State of Bypass Relay Signal 2
|
• Displays the bypass relay signal status.
|
BYPS_STAT
|
Bypass Off/Bypass On/Bypass Off fault/Bypass On fault
|
State of Bypass circuit within DC-DC Converter (i-ELOOP)
|
• Displays the bypass relay status.
|
C_MEAS_END_V
|
V
|
DCDC Input Voltage at end of measurement of capacitance at IR
|
• Displays the DC-DC converter (i-ELOOP) input voltage when the measurement of the capacitor (i-ELOOP) capacitance is completed.
|
C_MEAS_STAT
|
Completion/Incompletion/No directions
|
State of Electric capacity measurement
|
• Displays the measurement status of capacitor (i-ELOOP) capacitance.
|
C_MEAS_STR_V
|
V
|
DCDC Input Voltage at start of measurement of capacitance at IR
|
• Displays the DC-DC converter (i-ELOOP) input voltage when measurement of capacitor (i-ELOOP) capacitance is started.
|
CHG/DIS_STAT
|
Off/Charge (to Bat)/Discharge (to GND)/Fault (Off)/Fault (to Bat)/Fault (to GND)
|
State of charge/discharge circuit within DC-DC Converter (i-ELOOP)
|
• Displays the charge circuit status.
|
CONV_OUT_V
|
V
|
Converter circuit Output Voltage
|
• Displays the output voltage in voltage reduction circuit.
|
CONV_STAT
|
Ready/Power Output (Stop)/Power Output (Normal)/Power Output (Limit)/Safe Mode/Error
|
State of Converter circuit within DC-DC Converter (i-ELOOP)
|
• Displays the voltage reduction circuit operation status.
|
CAPA_TEMP
|
°C, °F
|
Capacitor (i-ELOOP) temperature
|
• Displays the capacitor (i-ELOOP) temperature.
|
DCDC_IN_V
|
V
|
DCDC Input Voltage (Input Terminal Voltage)
|
• Displays the DC-DC converter (i-ELOOP) input voltage.
|
DCDC_OUT_I
|
A
|
DCDC Output Current
|
• Displays the DC-DC converter (i-ELOOP) output current.
|
DCDC_OUT_V
|
V
|
DCDC Output Voltage (Output Terminal Voltage)
|
• Displays the DC-DC converter (i-ELOOP) output voltage.
|
DCDC_TEMP
|
°C, °F
|
DC-DC converter (i-ELOOP) temperature
|
• Displays the DC-DC converter (i-ELOOP) temperature
|
DEGEN_COUNT
|
—
|
Count of Degeneracy shift
|
• Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).
|
DEGEN_WARN
|
Ok/Degeneration warning/Degeneration
|
Warning of Degeneracy
|
• Displays the control status due to high temperature in the DC-DC converter (i-ELOOP).
|
IG_STAT
|
Off/On
|
State of IG signal input
|
• Displays the power supply status from the IG1 relay.
|
IR_LOAD_I
|
A
|
Output Current to compensating load at IR
|
• Displays the DC-DC converter (i-ELOOP) output current when the engine is restarted by i-stop.
|
IR_SW_STAT
|
Connect (On)/Disconnect (Off)/Fault (On)/Fault (Off)
|
State of IR circuit within DC-DC Converter (i-ELOOP)
|
• Displays the IG ON relay operation status.
|
OUT_M_CUR1
|
A
|
Output Mean Current in IG On (last time)
|
• Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous time the ignition was switched ON.
|
OUT_M_CUR2
|
A
|
Output Mean Current in IG On (2 times before)
|
• Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous 2 times that the ignition was switched ON.
|
OUT_M_CUR3
|
A
|
Output Mean Current in IG On (3 times before)
|
• Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous 3 times that the ignition was switched ON.
|
OUT_M_CUR4
|
A
|
Output Mean Current in IG On (4 times before)
|
• Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous 4 times that the ignition was switched ON.
|
OUT_M_CUR5
|
A
|
Output Mean Current in IG On (5 times before)
|
• Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous 5 times that the ignition was switched ON.
|
PURGE_RESLT
|
Charged/Purged/Fault
|
Result of charge purge on capacitor (i-ELOOP) after IG Off
|
• Displays the purge result of the capacitor (i-ELOOP) electrical charge after the ignition is switched off.
|