PID/DATA MONITOR INSPECTION [i-ELOOP]


id130201000500

1.  Connect the M-MDS to the DLC-2.

2.  After the vehicle is identified, select the following items from the initialization screen of the M-MDS.

(1)  Select “DataLogger”.
(2)  Select “Modules”.
(3)  Select “DCDC”.

3.  Select the applicable PID from the PID table.

4.  Verify the PID data according to the directions on the screen.

Note
•  The PID data screen function is used for monitoring the calculated value of input/output signals in the module. Therefore, if the monitored value of the output component is not within the specification, it is necessary to inspect the monitored value of input component corresponding to the applicable output part control. In addition, because the system does not display an output part malfunction as an abnormality in the monitored value, it is necessary to inspect the output component individually.
•  When detecting DTCs, PIDs related to a malfunctioning system may not display even if the module is normal. Therefore, if a PID is not displayed, it is necessary to verify the DTC, perform malfunction diagnosis of the DTC that was detected, and do repairs.

—: Not applicable

Item

Unit/Condition

description

Condition/Specification (Reference)

BYPS_COUNT
Count of Bypass Relay actuation
•  Displays operation amount of the bypass relay.
BYPS_RLY_STAT1
Low/High
State of Bypass Relay Signal 1
•  Displays the bypass relay signal status.
BYPS_RLY_STAT2
Low/High
State of Bypass Relay Signal 2
•  Displays the bypass relay signal status.
BYPS_STAT
Bypass Off/Bypass On/Bypass Off fault/Bypass On fault
State of Bypass circuit within DC-DC Converter (i-ELOOP)
•  Displays the bypass relay status.
―  Bypass relay OFF: Bypass OFF
―  Bypass relay ON: Bypass On
―  Bypass relay OFF (Fail): Off fault
―  Bypass relay ON (Fail): On fault
C_MEAS_END_V
V
DCDC Input Voltage at end of measurement of capacitance at IR
•  Displays the DC-DC converter (i-ELOOP) input voltage when the measurement of the capacitor (i-ELOOP) capacitance is completed.
C_MEAS_STAT
Completion/Incompletion/No directions
State of Electric capacity measurement
•  Displays the measurement status of capacitor (i-ELOOP) capacitance.
―  Measurement completed: Completion
―  Measurement not completed: Incompletion
―  No indication of measurement: No directions
C_MEAS_STR_V
V
DCDC Input Voltage at start of measurement of capacitance at IR
•  Displays the DC-DC converter (i-ELOOP) input voltage when measurement of capacitor (i-ELOOP) capacitance is started.
CHG/DIS_STAT
Off/Charge (to Bat)/Discharge (to GND)/Fault (Off)/Fault (to Bat)/Fault (to GND)
State of charge/discharge circuit within DC-DC Converter (i-ELOOP)
•  Displays the charge circuit status.
―  Charge circuit stopped: Off
―  Charged by capacitor (i-ELOOP) and battery: Charge (to Bat)
―  Charged by capacitor (i-ELOOP) and GND: Discharge (to GND)
―  Charge circuit malfunction (charge circuit stopped): Fault (Off)
―  Charge circuit malfunction (charged by capacitor (i-ELOOP) and battery): Fault (to Bat)
―  Charge circuit malfunction (charged by capacitor (i-ELOOP) and GND): Fault (to GND)
CONV_OUT_V
V
Converter circuit Output Voltage
•  Displays the output voltage in voltage reduction circuit.
CONV_STAT
Ready/Power Output (Stop)/Power Output (Normal)/Power Output (Limit)/Safe Mode/Error
State of Converter circuit within DC-DC Converter (i-ELOOP)
•  Displays the voltage reduction circuit operation status.
―  Preparation for voltage reduction completed: Ready
―  Output stopped: Power Output (Stop)
―  During output: Power Output (Normal)
―  Target output value not achieved due to limit: Power Output (Limit)
―  Self-protection status (voltage reduction circuit inoperable): Safe Mode
―  Voltage reduction circuit malfunction: Error
CAPA_TEMP
°C, °F
Capacitor (i-ELOOP) temperature
•  Displays the capacitor (i-ELOOP) temperature.
DCDC_IN_V
V
DCDC Input Voltage (Input Terminal Voltage)
•  Displays the DC-DC converter (i-ELOOP) input voltage.
DCDC_OUT_I
A
DCDC Output Current
•  Displays the DC-DC converter (i-ELOOP) output current.
DCDC_OUT_V
V
DCDC Output Voltage (Output Terminal Voltage)
•  Displays the DC-DC converter (i-ELOOP) output voltage.
DCDC_TEMP
°C, °F
DC-DC converter (i-ELOOP) temperature
•  Displays the DC-DC converter (i-ELOOP) temperature
DEGEN_COUNT
Count of Degeneracy shift
•  Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).
DEGEN_WARN
Ok/Degeneration warning/Degeneration
Warning of Degeneracy
•  Displays the control status due to high temperature in the DC-DC converter (i-ELOOP).
IG_STAT
Off/On
State of IG signal input
•  Displays the power supply status from the IG1 relay.
IR_LOAD_I
A
Output Current to compensating load at IR
•  Displays the DC-DC converter (i-ELOOP) output current when the engine is restarted by i-stop.
IR_SW_STAT
Connect (On)/Disconnect (Off)/Fault (On)/Fault (Off)
State of IR circuit within DC-DC Converter (i-ELOOP)
•  Displays the IG ON relay operation status.
―  IG ON relay ON: Connect (On)
―  IG ON relay OFF: Disconnect (Off)
―  IG ON relay ON (Fail): Fault (On)
―  IG ON relay OFF (Fail): Fault (Off)
OUT_M_CUR1
A
Output Mean Current in IG On (last time)
•  Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous time the ignition was switched ON.
OUT_M_CUR2
A
Output Mean Current in IG On (2 times before)
•  Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous 2 times that the ignition was switched ON.
OUT_M_CUR3
A
Output Mean Current in IG On (3 times before)
•  Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous 3 times that the ignition was switched ON.
OUT_M_CUR4
A
Output Mean Current in IG On (4 times before)
•  Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous 4 times that the ignition was switched ON.
OUT_M_CUR5
A
Output Mean Current in IG On (5 times before)
•  Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous 5 times that the ignition was switched ON.
PURGE_RESLT
Charged/Purged/Fault
Result of charge purge on capacitor (i-ELOOP) after IG Off
•  Displays the purge result of the capacitor (i-ELOOP) electrical charge after the ignition is switched off.