WASTEGATE SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-D 2.2]
id0113z7266100
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 2.2].)
2. Remove the battery and the battery tray. (See BATTERY REMOVAL/INSTALLATION [SKYACTIV-D 2.2].)
3. Remove in the order shown in the figure.
ATX
am3zzw00015322
|
MTX
ac5wzw00004692
|
1
|
Vacuum pipe bracket
|
2
|
Vacuum hose No.1
|
3
|
Vacuum hose No.2
|
4
|
Vacuum hose No.3
|
5
|
Wastegate solenoid valve
|
4. Install in the reverse order of removal.
Vacuum Hose No.3 Installation Note
1. Install vacuum hose No.3 as shown in the figure.
Wastegate solenoid valve side
am3zzw00016712
|
Vacuum pipe bracket side
am3zzw00016713
|
Vacuum Hose No.2 Installation Note
1. Install vacuum hose No.2 as shown in the figure.
Wastegate solenoid valve side
am3zzw00016714
|
Wastegate valve actuator side
am3zzw00016715
|
Vacuum Hose No.1 Installation Note
1. Install vacuum hose No.1 as shown in the figure.
Wastegate solenoid valve side
am3zzw00016716
|
Vacuum pipe bracket side
am3zzw00016717
|
Vacuum hose structural view
1. Verify that the vacuum hose is installed correctly as shown in the figure.
Whole figure (ATX)
ac5wzw00004669
|
Whole figure (MTX)
ac5wzw00004670
|
Wastegate solenoid valve side (ATX)
ac5wzw00004701
|
Wastegate solenoid valve side (MTX)
ac5wzw00004702
|
Vacuum pipe bracket side (ATX)
ac5wzw00004703
|
Vacuum pipe bracket side (MTX)
ac5wzw00004704
|