WASTEGATE SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-D 2.2]


id0113z7266100

Caution
•  If the vacuum hose is installed incorrectly, it could cause a vehicle malfunction. To prevent this, refer to “VACUUM HOSE STRUCTURAL VIEW” and install the vacuum hose correctly. (See Vacuum hose structural view.)

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 2.2].)

2.  Remove the battery and the battery tray. (See BATTERY REMOVAL/INSTALLATION [SKYACTIV-D 2.2].)

3.  Remove in the order shown in the figure.

ATX

am3zzw00015322

MTX

ac5wzw00004692

1
Vacuum pipe bracket
2
Vacuum hose No.1
3
Vacuum hose No.2
4
Vacuum hose No.3
5
Wastegate solenoid valve

4.  Install in the reverse order of removal.


Vacuum Hose No.3 Installation Note

1.  Install vacuum hose No.3 as shown in the figure.

Wastegate solenoid valve side

am3zzw00016712

Vacuum pipe bracket side

am3zzw00016713


Vacuum Hose No.2 Installation Note

1.  Install vacuum hose No.2 as shown in the figure.

Wastegate solenoid valve side

am3zzw00016714

Wastegate valve actuator side

am3zzw00016715


Vacuum Hose No.1 Installation Note

1.  Install vacuum hose No.1 as shown in the figure.

Wastegate solenoid valve side

am3zzw00016716

Vacuum pipe bracket side

am3zzw00016717


Vacuum hose structural view

1.  Verify that the vacuum hose is installed correctly as shown in the figure.

Whole figure (ATX)

ac5wzw00004669

Whole figure (MTX)

ac5wzw00004670

Wastegate solenoid valve side (ATX)

ac5wzw00004701

Wastegate solenoid valve side (MTX)

ac5wzw00004702

Vacuum pipe bracket side (ATX)

ac5wzw00004703

Vacuum pipe bracket side (MTX)

ac5wzw00004704