GENERATOR INSPECTION [SKYACTIV-D 1.5]
id0117q6800300
Charging System Warning Light
1. Verify that the battery is fully charged. (See BATTERY INSPECTION [SKYACTIV-G 1.5, SKYACTIV-G 2.0, SKYACTIV-G 2.5].)
2. Verify that the assembly condition of the drive belt is normal. (See DRIVE BELT INSPECTION [SKYACTIV-D 1.5].)
3. Switch the ignition ON (engine off), verify that the charging system warning light illuminates.
4. Verify that the charging system warning light turns off after the engine is started.
Generator
Generator voltage inspection
1. Verify that the battery is fully charged. (See BATTERY INSPECTION [SKYACTIV-G 1.5, SKYACTIV-G 2.0, SKYACTIV-G 2.5].)
2. Verify that the assembly condition of the drive belt is normal. (See DRIVE BELT INSPECTION [SKYACTIV-D 1.5].)
3. Turn off all electrical loads.
4. Start the engine.
5. Verify that the generator rotates smoothly without any noise while the engine is running.
6. Measure the voltage at each terminal using a tester.
|
Generator current inspection
1. Verify that the battery is fully charged. (See BATTERY INSPECTION [SKYACTIV-G 1.5, SKYACTIV-G 2.0, SKYACTIV-G 2.5].)
2. Verify that the assembly condition of the drive belt is normal. (See DRIVE BELT INSPECTION [SKYACTIV-D 1.5].)
3. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 1.5].)
4. Connect a tester, which can read 120 A or more, between generator terminal 1A and generator terminal 1A cable.
5. Connect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 1.5].)
6. Turn off all electrical loads.
7. Start the engine.
8. Turn the electrical loads (such as headlights, blower motor, rear window defogger, brake lights) on and verify that the current reading increases more than the minimum value indicated below.
Generator generated current (reference value) [Ambient temperature: 20 °C {68 °F}, Engine hot]
Engine speed (rpm) |
Terminal 1A voltage (V) |
Generator output current (A) |
---|---|---|
1,000
|
13
|
125
|
1,000
|
15
|
128
|
2,000
|
13
|
148
|
2,000
|
15
|
163
|
Generator Internal Parts
Rotor
1. Measure the resistance between the slip rings using a ohmmeter.
|
2. Verify that there is no continuity between the slip ring and core using a ohmmeter.
|
3. Inspect the slip ring surface condition.
Stator coil
1. Verify that the continuity is as indicated in the table.
|
|
2. Verify that there is no continuity between the stator coil leads and core using a ohmmeter.
|
Brush
1. Inspect brushes for wear.
|
Brush spring
1. Measure the force of the brush spring using a spring pressure gauge.
2. Read the spring pressure gauge at the brush tip projection of 2 mm {0.08 in}.
|
Rectifier (Using an analog circuit tester)
1. Inspect for continuity of the diodes using an analog circuit tester.
|
Specification
Analog circuit tester |
Continuity |
|
---|---|---|
Negative |
Positive |
|
E
|
P1, P2, P3, P4, P5, P6
|
Yes
|
B
|
No
|
|
P1, P2, P3, P4, P5, P6
|
E
|
No
|
B
|
Yes
|
Rectifier (Using a digital circuit tester)
1. Inspect for continuity of the diodes using a digital circuit tester.
Specification
Digital circuit tester |
Continuity |
|
---|---|---|
Negative |
Positive |
|
E
|
P1, P2, P3, P4, P5, P6
|
No
|
B
|
Yes
|
|
P1, P2, P3, P4, P5, P6
|
E
|
Yes
|
B
|
No
|
Bearing
1. Inspect for abnormal noise, looseness, and sticking.
|