BLOW-BY HEATER INSPECTION [SKYACTIV-D 1.5]


id0140q2446500

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 1.5].)

2.  Disconnect the blow-by heater connector.

am3zzw00017815

3.  Measure the resistance between the blow-by heater terminals A and B.

am3zzw00017816

•  If not as specified, replace the blow-by heater. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [SKYACTIV-D 1.5].)
Blow-by heater resistance
6—10 ohms [normal temperature]