TRANSAXLE FLUID TEMPERATURE (TFT) SENSOR INSPECTION [FN4A-EL]
id051701292100
On-Vehicle Inspection
1. Perform the following procedures.
|
2. Measure the resistance between the coupler component terminals E and H.
|
TFT sensor specification
ATF temperature (°C{°F}) |
Resistance (kilohm) |
---|---|
-20 {-4}
|
236—324
|
0 {32}
|
84.3—110
|
20 {68}
|
33.5—42.0
|
40 {104}
|
14.7—17.9
|
60 {140}
|
7.08—8.17
|
80 {176}
|
3.61—4.15
|
100 {212}
|
1.96—2.24
|
120 {248}
|
1.13—1.28
|
130 {266}
|
0.87—0.98
|
Off-Vehicle Inspection
1. Place the TFT sensor and a thermometer in ATF as shown, and heat the ATF gradually.
|
2. Measure the resistance between the coupler component terminals E and H.
|
TFT sensor specification
ATF temperature (°C{°F}) |
Resistance (kilohm) |
---|---|
-20 {-4}
|
236—324
|
0 {32}
|
84.3—110
|
20 {68}
|
33.5—42.0
|
40 {104}
|
14.7—17.9
|
60 {140}
|
7.08—8.17
|
80 {176}
|
3.61—4.15
|
100 {212}
|
1.96—2.24
|
120 {248}
|
1.13—1.28
|
130 {266}
|
0.87—0.98
|