SECURITY INDICATOR LIGHT: 21, DTC: B13D4:00/P1260:00 [IMMOBILIZER SYSTEM]
id0902e4028100
Description |
Insufficient remote transmitter programming number |
---|---|
Detection condition
|
• Start stop unit detects that the number of programmed remote transmitters is less than 2.
|
Fail-safe function
|
Not applicable
|
Possible cause
|
• Insufficient number of remote transmitters programmed
• Start stop unit malfunction
|
System wiring diagram
|
Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY NUMBER OF PROGRAMMED REMOTE TRANSMITTER
• Display PID NUM_TRNSMIT using the M-MDS.
• Is the number of programmed remote transmitters less than 2?
|
Yes
|
Perform the additional remote transmitter programming, then go to the next step.
|
No
|
Go to the next step.
|
||
2
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Clear the DTC for the immobilizer system using the M-MDS.
• Retrieve the immobilizer system DTCs using the M-MDS.
• Is the security indicator light: 21, DTC B13D4:00/P1260:00 displayed?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the start stop unit.
Go to the next step.
|
No
|
Go to the next step.
|
||
3
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|