DTC U2100:00 [INSTRUMENT CLUSTER]
id0902e8999600
Description |
Instrument cluster configuration error |
---|---|
Detection condition
|
• Instrument cluster configuration error detected as follows:
|
Fail-safe function
|
Not applicable
|
Possible cause
|
• Instrument cluster configuration error
• Instrument cluster malfunction
|
System wiring diagram
|
Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
PERFORM INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA)
• Using the M-MDS, perform the instrument cluster configuration (using As-Built data).
• Clear the DTC for the instrument cluster using the M-MDS.
• Retrieve the instrument cluster DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step.
|
No
|
Go to Step 3.
|
||
2
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Clear the DTC for the instrument cluster using the M-MDS.
• Retrieve the instrument cluster DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the instrument cluster.
Go to the next step.
|
No
|
Go to the next step.
|
||
3
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|