DTC U0300:00 [INSTRUMENT CLUSTER]


id0902e8999700

Description

Instrument cluster configuration error

Detection condition
•  Instrument cluster configuration error (incorrect value write) detected.
Fail-safe function
Not applicable
Possible cause
•  Instrument cluster configuration error
•  Instrument cluster malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

Step

Inspection

Action

1
PERFORM INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA)
•  Using the M-MDS, perform the instrument cluster configuration (using As-Built data).
•  Clear the DTC for the instrument cluster using the M-MDS.
•  Retrieve the instrument cluster DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step.
No
Go to Step 3.
2
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Clear the DTC for the instrument cluster using the M-MDS.
•  Retrieve the instrument cluster DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the instrument cluster.
Go to the next step.
No
Go to the next step.
3
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.