DTC U3000:09 [BLIND SPOT MONITORING (BSM)]


id0902i3393100

Description

BSM control module internal malfunction

Detection condition
•  BSM control module detected a malfunction inside the voltage control oscillator.
Fail-safe function
•  Blind spot monitoring (BSM) system is stopped.
Possible cause
•  BSM control module malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

Step

Inspection

Action

1
PERFORM DTC INSPECTION AND VERIFY BSM CONTROL MODULE MALFUNCTION
•  Clear the DTC for the BSM control module using the M-MDS.
•  Retrieve the BSM control module DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Replace the BSM control module, then go to the next step.
No
Go to the next step.
2
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.