DTC U3000:09 [BLIND SPOT MONITORING (BSM)]
id0902i3393100
Description |
BSM control module internal malfunction |
---|---|
Detection condition
|
• BSM control module detected a malfunction inside the voltage control oscillator.
|
Fail-safe function
|
• Blind spot monitoring (BSM) system is stopped.
|
Possible cause
|
• BSM control module malfunction
|
System wiring diagram
|
Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
PERFORM DTC INSPECTION AND VERIFY BSM CONTROL MODULE MALFUNCTION
• Clear the DTC for the BSM control module using the M-MDS.
• Retrieve the BSM control module DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Replace the BSM control module, then go to the next step.
|
No
|
Go to the next step.
|
||
2
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|