DTC U2300:64 [BLIND SPOT MONITORING (BSM)]
id0902i3404300
Description |
Instrument cluster configuration error |
---|---|
Detection condition
|
• Instrument cluster configuration error (signal error) detected.
|
Fail-safe function
|
• Blind spot monitoring (BSM) system is stopped.
|
Possible cause
|
• Instrument cluster configuration error
• BSM control module malfunction
|
System wiring diagram
|
Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
PERFORM INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA)
• Using the M-MDS, perform the instrument cluster configuration (using As-Built data).
• Clear the DTC for the BSM control module using the M-MDS.
• Retrieve the BSM control module DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step.
|
No
|
Go to Step 3.
|
||
2
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Clear the DTC for the BSM control module using the M-MDS.
• Retrieve the BSM control module DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the BSM control module.
Go to the next step.
|
No
|
Go to the next step.
|
||
3
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|