REFRIGERANT PRESSURE SENSOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER]


id0740a1817300


MZR 1.6, SKYACTIV-G 1.5, SKYACTIV-G 2.0, SKYACTIV-G 2.5

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [MZR 1.6].)(See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 1.5, SKYACTIV-G 2.0, SKYACTIV-G 2.5].)

2.  Discharge the refrigerant. (See REFRIGERANT CHARGING.)

3.  Disconnect the refrigerant pressure sensor connector.

am3uuw00010226

4.  Loosen the refrigerant pressure sensor using two spanners.

am6xuw00006150

Tightening torque
10—11 N·m {102—112 kgf·cm, 89—97 in·lbf}

5.  Remove the refrigerant pressure sensor.

am3uuw00010227

Caution
•  If moisture or foreign matter enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign matter out of the cycle.

6.  Install in the reverse order of removal. (See Refrigerant pressure sensor installation note.)

7.  Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST.)


Refrigerant pressure sensor installation note

1.  Apply compressor oil to the O-rings and connect the joints.


SKYACTIV-D 1.5, SKYACTIV-D 2.2

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 1.5].)(See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 2.2].)

2.  Discharge the refrigerant. (See REFRIGERANT CHARGING.)

3.  Disconnect the connector.

am3zzw00017777

4.  Detach the fastener.

5.  Remove the bolts.

6.  Remove the clip.

7.  Set the PCM out of the way.

am3zzw00015143

8.  Disconnect the refrigerant pressure sensor connector.

am3zzw00015144

9.  Loosen the refrigerant pressure sensor using two spanners.

am6xuw00006150

Tightening torque
10—11 N·m {102—112 kgf·cm, 89—97 in·lbf}

10.  Remove the refrigerant pressure sensor.

am3zzw00015145

Caution
•  If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.

11.  Install in the reverse order of removal. (See Refrigerant pressure sensor installation note.)

12.  Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST.)


Refrigerant pressure sensor installation note

1.  Apply compressor oil to the O-rings and connect the joints.