NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 1.5, SKYACTIV-G 2.0, SKYACTIV-G 2.5]
id0117i6800800
Required Procedure After Negative Battery Cable Terminal Disconnection/Connection
System name |
Conditions after disconnecting the negative battery cable terminal |
Required procedure |
Reference |
||
---|---|---|---|---|---|
Before disconnecting negative battery cable terminal |
After connecting negative battery cable terminal |
||||
Power window system
|
Reset to initial setting and auto-function is disabled.
|
—
|
Perform the power window system initial setting.
|
||
Sunroof system
|
Reset to initial setting and function is disabled.
|
—
|
Perform the sunroof system initial setting.
|
||
Clock and audio
|
Clock display and audio system memory are reset.
|
Verify the setting content.
|
Set the verified content before disconnecting negative battery cable terminal.
|
—
|
|
i-stop system (With i-stop)
|
Specified information in the PCM cleared and the i-stop does not operate normally.
|
Verify PID “BATT_SOC” value and record. *1
|
Perform battery condition initial setting (i-stop setting). *2
|
||
Tire pressure monitoring system (TPMS)
|
The tire pressure monitoring system detection accuracy decreases.
|
—
|
Perform the tire pressure monitoring system initialization.
|
With i-stop
Negative battery cable terminal disconnection
1. Connect the M-MDS to the DLC-2.
2. Switch the ignition ON (engine off).
3. Verify the “BATT_SOC” value using the M-MDS data logger function. (See ON-BOARD DIAGNOSTIC TEST [SKYACTIV-G 1.5, SKYACTIV-G 2.0, SKYACTIV-G 2.5].)
4. Record the “BATT_SOC” value.
5. Switch the ignition off.
6. Disconnect the current sensor connector.
7. Disconnect the negative battery cable terminal.
|
Negative battery cable terminal connection
|
1. Perform battery condition initial setting (i-stop setting). (See BATTERY CONDITION INITIALIZATION SETTING (i-stop SETTING) [SKYACTIV-G 1.5, SKYACTIV-G 2.0, SKYACTIV-G 2.5].)
2. Perform services not related to i-stop control which are required after connecting the negative battery cable terminal. (See Required Procedure After Negative Battery Cable Terminal Disconnection/Connection.)
Without i-stop
Negative battery cable terminal disconnection
1. Switch the ignition to off.
2. Disconnect the negative battery cable.
Negative battery cable terminal connection
1. Connect the negative battery cable terminal.
2. Perform services which are required after connecting the negative battery cable terminal. (See Required Procedure After Negative Battery Cable Terminal Disconnection/Connection.)