DTC U2300:56 [BLIND SPOT MONITORING (BSM)]
id0902i3401400
Description |
Configuration data unmatched with instrument cluster |
---|---|
Detection condition
|
• Configuration data of the BSM control module and instrument cluster are not matched.
|
Fail-safe function
|
• Blind spot monitoring (BSM) system is stopped.
|
Possible cause
|
• DTCs are stored in the instrument cluster.
• Instrument cluster configuration data error
• BSM control module malfunction
|
System wiring diagram
|
Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY INSTRUMENT CLUSTER DTCs
• Retrieve the instrument cluster DTCs using the M-MDS.
• Are any DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
Go to the next step.
|
||
2
|
RESET INSTRUMENT CLUSTER CONFIGURATION DATA
• Using the M-MDS, perform the instrument cluster configuration (using As-Built data).
• Clear the DTC for the BSM control module using the M-MDS.
• Switch the ignition ON (engine off or on) and wait for 30 s or more.
• Retrieve the BSM control module DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step.
|
No
|
Go to Step 4.
|
||
3
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Clear the DTC for the BSM control module using the M-MDS.
• Switch the ignition ON (engine off or on) and wait for 30 s or more.
• Retrieve the BSM control module DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the BSM control module.
Go to the next step.
|
No
|
Go to the next step.
|
||
4
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|