DTC B1252:1D [CONNECTIVITY MASTER UNIT]


id0902n7105200

Description

Auxiliary jack/USB port/SD card slot hub circuit malfunction

Detection condition
•  The connectivity master unit (CMU) detects over-current (550 mA or more) in auxiliary jack/USB port/SD card slot hub circuit with the ignition switched ON (engine off or on).
Fail-safe function
Not applicable
Possible cause
•  Auxiliary jack/USB port/SD card slot hub connector or terminal malfunction
•  Connectivity master unit (CMU) connector or terminal malfunction
•  Short to ground in wiring harness between connectivity master unit (CMU) terminal 4C and auxiliary jack/USB port/SD card slot hub terminal 2C
•  Auxiliary jack/USB port/SD card slot hub malfunction
•  Connectivity master unit (CMU) malfunction

Diagnostic Procedure

Step

Inspection

Action

1
INSPECT AUXILIARY JACK/USB PORT/SD CARD SLOT HUB CONNECTOR CONDITION
•  Switch the ignition off.
•  Disconnect the auxiliary jack/USB port/SD card slot hub connector.
•  Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
•  Is the connector normal?
Yes
Go to the next step.
No
Repair or replace the connector, then go to Step 5.
2
INSPECT CONNECTIVITY MASTER UNIT (CMU) CONNECTOR CONDITION
•  Disconnect the connectivity master unit (CMU) connector.
•  Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
•  Is the connector normal?
Yes
Go to the next step.
No
Repair or replace the connector, then go to Step 5.
3
INSPECT AUXILIARY JACK/USB PORT/SD CARD SLOT HUB CIRCUIT FOR SHORT TO GROUND
•  Verify that the auxiliary jack/USB port/SD card slot hub connector and the connectivity master unit (CMU) connector are disconnected.
•  Inspect for continuity between auxiliary jack/USB port/SD card slot hub terminal 2C (wiring harness-side) and body ground.
•  Is there continuity?
Yes
Refer to the wiring diagram and verify if there is a common connector between connectivity master unit (CMU) terminal 4C and auxiliary jack/USB port/SD card slot hub terminal 2C.
If there is a common connector:
•  Inspect the common connector and terminals for corrosion, damage, or disconnection and the common wiring harnesses for short to ground to determine the malfunctioning location.
•  Repair or replace the malfunctioning location.
If there is no common connector:
•  Repair or replace the wiring harness which is shorted to ground.
Go to Step 5.
No
Go to the next step.
4
PERFORM DTC INSPECTION AND VERIFY IF MALFUNCTIONING LOCATION IS AUXILIARY JACK/USB PORT/SD CARD SLOT HUB
•  Always reconnect all disconnected connectors.
•  Clear the DTC for the connectivity master unit (CMU) using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 7 s or more.
•  Perform the DTC inspection for the connectivity master unit (CMU) using the M-MDS.
•  Is the same DTC displayed?
Yes
Replace the auxiliary jack/USB port/SD card slot hub, then go to the next step.
No
Go to Step 6.
5
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Always reconnect all disconnected connectors.
•  Clear the DTC for the connectivity master unit (CMU) using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 7 s or more.
•  Perform the DTC inspection for the connectivity master unit (CMU) using the M-MDS.
•  Is the same DTC displayed?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the connectivity master unit (CMU).
Go to the next step.
No
Go to the next step.
6
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair the malfunctioning location according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.