DTC U3004:11 [START STOP UNIT]


id0902p6025000

Description

ACC relay circuit malfunction

Detection condition
•  Start stop unit detects that the ACC relay output monitor voltage of less than specification for 0.05 s or more with the ignition switched to ACC or ON (engine off or on).
Fail-safe function
Not applicable
Possible cause
•  ACC relay malfunction
•  Start stop unit connector or terminal malfunction
•  Short to ground in wiring harness between ACC relay terminal A and start stop unit terminal 2C
•  Start stop unit malfunction

Diagnostic Procedure

Step

Inspection

Action

1
INSPECT ACC RELAY
•  Switch the ignition off.
•  Remove the ACC relay.
•  Inspect the ACC relay.
•  Is the ACC relay normal?
Yes
Go to the next step.
No
Replace the ACC relay, then go to Step 4.
2
INSPECT START STOP UNIT CONNECTOR CONDITION
•  Disconnect the start stop unit connector.
•  Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
•  Is the connector normal?
Yes
Go to the next step.
No
Repair or replace the connector, then go to Step 4.
3
INSPECT FOR SHORT TO GROUND IN ACC RELAY CIRCUIT
•  Verify that the ACC relay is removed.
•  Verify that the start stop unit connector is disconnected.
•  Inspect for continuity between ACC relay terminal A (wiring harness-side) and body ground.
•  Is there continuity?
Yes
Refer to the wiring diagram and verify whether or not there is a common connector between ACC relay terminal A and start stop unit terminal 2C.
If there is a common connector:
•  Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
•  Repair or replace the malfunctioning part.
If there is no common connector:
•  Repair or replace the wiring harness which has a short to ground.
Go to the next step.
No
Go to the next step.
4
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Always reconnect all disconnected connectors.
•  Clear the DTC for the start stop unit using the M-MDS.
•  Switch the ignition to ACC or ON (engine off or on) and wait for 1 s or more.
•  Retrieve the start stop unit DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the start stop unit.
Go to the next step.
No
Go to the next step.
5
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.