DTC U3004:12 [START STOP UNIT]
id0902p6025100
Description |
ACC relay circuit malfunction |
---|---|
Detection condition
|
• Start stop unit detects that the ACC relay output monitor voltage of 2.5 V or more for 0.5 s or more with the ignition switched off.
|
Fail-safe function
|
• Door locking operation inhibited while under i-stop control. (With i-stop system)
|
Possible cause
|
• ACC relay malfunction
• Start stop unit connector or terminal malfunction
• Short to power supply in wiring harness between ACC relay terminal A and start stop unit terminal 2C
• Start stop unit malfunction
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT ACC RELAY
• Switch the ignition off.
• Disconnect the negative battery cable.
• Remove the ACC relay.
(See RELAY LOCATION.)
• Inspect the ACC relay.
(See RELAY INSPECTION.)
• Is the ACC relay normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the ACC relay, then go to Step 4.
(See RELAY LOCATION.)
|
||
2
|
INSPECT START STOP UNIT CONNECTOR CONDITION
• Disconnect the start stop unit connector.
• Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
• Is the connector normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the connector, then go to Step 4.
|
||
3
|
INSPECT FOR SHORT TO POWER SUPPLY IN ACC RELAY CIRCUIT
• Always reconnect all disconnected connectors.
• Reconnect the negative battery cable.
• Measure the voltage at the start stop unit terminal 2C (wiring harness-side).
• Is the voltage 2.5 V or more?
|
Yes
|
Refer to the wiring diagram and verify whether or not there is a common connector between ACC relay terminal A and start stop unit terminal 2C.
If there is a common connector:
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.
• Repair or replace the malfunctioning part.
If there is no common connector:
• Repair or replace the wiring harness which has a short to power supply.
Go to the next step.
|
No
|
Go to the next step.
|
||
4
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Always reconnect all disconnected connectors.
• Reconnect the negative battery cable.
• Clear the DTC for the start stop unit using the M-MDS.
• Switch the ignition off and wait for 1 s or more.
• Retrieve the start stop unit DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the start stop unit.
Go to the next step.
|
No
|
Go to the next step.
|
||
5
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [START STOP UNIT].)
|
No
|
DTC troubleshooting completed.
|