No.1 MESSAGE RELATED TO i-ELOOP SYSTEM MALFUNCTION INDICATED IN DISPLAY [i-ELOOP]


id130301003100


Description

•  Message related to i-ELOOP system malfunction indicated in display.
•  Master warning light is illuminated

Possible Cause


i-ELOOP-related component malfunction (DTCs are detected)

•  Capacitor (i-ELOOP) malfunction
•  DC-DC converter (i-ELOOP) malfunction
•  PCM malfunction
•  i-ELOOP-related part wiring harness malfunction


Instrument cluster incorrect display

•  Instrument cluster malfunction


Diagnostic Procedure

STEP

INSPECTION

RESULTS

ACTION

1
VERIFY DTCs
•  Using the M-MDS, display the DTCs related to the PCM, DC-DC converter (i-ELOOP), and instrument cluster.
•  Are any DTCs displayed?
Yes
Repair the malfunctioning part according to the applicable DTC troubleshooting.
No
Inspect the instrument cluster and replace it if there is any malfunction.