DTC TABLE [FULL-AUTO AIR CONDITIONER]
id0702c1801700
DTC No. |
Warning/indicator light |
System malfunction location |
Fail-safe function |
Drive cycle |
Self test type*1 |
Memory function |
Page |
---|---|---|---|---|---|---|---|
B1081:71*2
|
—
|
• Driver-side air mix actuator motor lock (L.H.D.)
• Passenger-side air mix actuator motor lock (R.H.D.)
|
X
|
—
|
C
|
X
|
|
B1082:71*2
|
—
|
• Passenger-side air mix actuator motor lock (L.H.D.)
• Driver-side air mix actuator motor lock (R.H.D.)
|
X
|
—
|
C
|
X
|
|
B1086:71
|
—
|
Airflow mode actuator motor lock
|
X
|
—
|
C
|
X
|
|
B13AA:71*3
|
—
|
Air mix actuator motor lock
|
X
|
—
|
C
|
X
|
|
B13AB:12*3
|
—
|
Air mix actuator (potentiometer) circuit short to power supply
|
X
|
—
|
C, D
|
X
|
|
B13AB:13*3
|
—
|
Air mix actuator (potentiometer) circuit short to power supply
|
X
|
—
|
C, D
|
X
|
|
B1A61:11
|
—
|
Cabin temperature sensor circuit short to ground
|
X
|
—
|
C, D
|
X
|
|
B1A61:13
|
—
|
Cabin temperature sensor circuit open
|
X
|
—
|
C, D
|
X
|
|
B1A63:12
|
—
|
Solar radiation sensor (RH) circuit short to power supply
|
X
|
—
|
C, D
|
X
|
|
B1A63:13
|
—
|
Solar radiation sensor (RH) circuit open
|
X
|
—
|
D
|
X
|
|
B1A64:12
|
—
|
Solar radiation sensor (LH) circuit short to power supply
|
X
|
—
|
C, D
|
X
|
|
B1A64:13
|
—
|
Solar radiation sensor (LH) circuit open
|
X
|
—
|
D
|
X
|
|
B1B71:11
|
—
|
Evaporator temperature sensor circuit short to ground
|
X
|
—
|
C, D
|
X
|
|
B1B71:13
|
—
|
Evaporator temperature sensor circuit open
|
X
|
—
|
C, D
|
X
|
|
B1C1A:11*2
|
—
|
• Driver-side air mix actuator (potentiometer) circuit short to ground (L.H.D.)
• Passenger-side air mix actuator (potentiometer) circuit short to ground (R.H.D.)
|
X
|
—
|
C, D
|
X
|
|
B1C1A:13*2
|
—
|
• Driver-side air mix actuator (potentiometer) circuit open (L.H.D.)
• Passenger-side air mix actuator (potentiometer) circuit open (R.H.D.)
|
X
|
—
|
C, D
|
X
|
|
B1C1B:11*2
|
—
|
• Passenger-side air mix actuator (potentiometer) circuit short to ground (L.H.D.)
• Driver-side air mix actuator (potentiometer) circuit short to ground (R.H.D.)
|
X
|
—
|
C, D
|
X
|
|
B1C1B:13*2
|
—
|
• Passenger-side air mix actuator (potentiometer) circuit open (L.H.D.)
• Driver-side air mix actuator (potentiometer) circuit open (R.H.D.)
|
X
|
—
|
C, D
|
X
|
|
B1C1C:11*2
|
—
|
Airflow mode actuator (potentiometer) circuit short to ground
|
X
|
—
|
C, D
|
X
|
|
B1C1C:12*3
|
—
|
Airflow mode actuator (potentiometer) circuit short to power supply
|
X
|
—
|
C, D
|
X
|
|
B1C1C:13
|
—
|
Airflow mode actuator (potentiometer) circuit open
|
X
|
—
|
C, D
|
X
|
|
U0010:88
|
—
|
Unit communication error (MS-CAN)
|
X
|
—
|
C, D
|
X
|
|
U0155:00
|
—
|
Communication error with instrument cluster
|
X
|
—
|
C
|
X
|
|
U0423:68
|
—
|
Invalid data received from Instrument cluster
|
X
|
—
|
C, D
|
X
|
|
U200D:11
|
—
|
Climate control unit circuit voltage (+5V) circuit short to ground
|
—
|
—
|
C, D
|
X
|
|
U2300:54
|
—
|
Configuration error (data not received)
|
X
|
—
|
C, D
|
X
|
|
U2300:55
|
—
|
Configuration error (not configured)
|
X
|
—
|
C, D
|
—
|
|
U2300:56
|
—
|
Configuration error (ineffective/non-interchangeable data read)
|
X
|
—
|
C, D
|
X
|
|
U2300:64
|
—
|
Configuration error (error value read)
|
X
|
—
|
C, D
|
X
|
|
U3003:16
|
—
|
Climate control unit power supply circuit voltage below threshold (9.98 V or less)
|
—
|
—
|
C, D
|
X
|
|
U3003:17
|
—
|
Climate control unit power supply circuit voltage above threshold (16.21 V or more)
|
—
|
—
|
C, D
|
X
|
|
U300E:13
|
—
|
Climate control unit power supply circuit open (IG1 or IG2)
|
—
|
—
|
C, D
|
X
|