DTC TABLE [FULL-AUTO AIR CONDITIONER]


id0702c1801700

X: Applicable
—: Not applicable

DTC No.

Warning/indicator light

System malfunction location

Fail-safe function

Drive cycle

Self test type*1

Memory function

Page

B1081:71*2
•  Driver-side air mix actuator motor lock (L.H.D.)
•  Passenger-side air mix actuator motor lock (R.H.D.)
X
C
X
B1082:71*2
•  Passenger-side air mix actuator motor lock (L.H.D.)
•  Driver-side air mix actuator motor lock (R.H.D.)
X
C
X
B1086:71
Airflow mode actuator motor lock
X
C
X
B13AA:71*3
Air mix actuator motor lock
X
C
X
B13AB:12*3
Air mix actuator (potentiometer) circuit short to power supply
X
C, D
X
B13AB:13*3
Air mix actuator (potentiometer) circuit short to power supply
X
C, D
X
B1A61:11
Cabin temperature sensor circuit short to ground
X
C, D
X
B1A61:13
Cabin temperature sensor circuit open
X
C, D
X
B1A63:12
Solar radiation sensor (RH) circuit short to power supply
X
C, D
X
B1A63:13
Solar radiation sensor (RH) circuit open
X
D
X
B1A64:12
Solar radiation sensor (LH) circuit short to power supply
X
C, D
X
B1A64:13
Solar radiation sensor (LH) circuit open
X
D
X
B1B71:11
Evaporator temperature sensor circuit short to ground
X
C, D
X
B1B71:13
Evaporator temperature sensor circuit open
X
C, D
X
B1C1A:11*2
•  Driver-side air mix actuator (potentiometer) circuit short to ground (L.H.D.)
•  Passenger-side air mix actuator (potentiometer) circuit short to ground (R.H.D.)
X
C, D
X
B1C1A:13*2
•  Driver-side air mix actuator (potentiometer) circuit open (L.H.D.)
•  Passenger-side air mix actuator (potentiometer) circuit open (R.H.D.)
X
C, D
X
B1C1B:11*2
•  Passenger-side air mix actuator (potentiometer) circuit short to ground (L.H.D.)
•  Driver-side air mix actuator (potentiometer) circuit short to ground (R.H.D.)
X
C, D
X
B1C1B:13*2
•  Passenger-side air mix actuator (potentiometer) circuit open (L.H.D.)
•  Driver-side air mix actuator (potentiometer) circuit open (R.H.D.)
X
C, D
X
B1C1C:11*2
Airflow mode actuator (potentiometer) circuit short to ground
X
C, D
X
B1C1C:12*3
Airflow mode actuator (potentiometer) circuit short to power supply
X
C, D
X
B1C1C:13
Airflow mode actuator (potentiometer) circuit open
X
C, D
X
U0010:88
Unit communication error (MS-CAN)
X
C, D
X
U0155:00
Communication error with instrument cluster
X
C
X
U0423:68
Invalid data received from Instrument cluster
X
C, D
X
U200D:11
Climate control unit circuit voltage (+5V) circuit short to ground
C, D
X
U2300:54
Configuration error (data not received)
X
C, D
X
U2300:55
Configuration error (not configured)
X
C, D
U2300:56
Configuration error (ineffective/non-interchangeable data read)
X
C, D
X
U2300:64
Configuration error (error value read)
X
C, D
X
U3003:16
Climate control unit power supply circuit voltage below threshold (9.98 V or less)
C, D
X
U3003:17
Climate control unit power supply circuit voltage above threshold (16.21 V or more)
C, D
X
U300E:13
Climate control unit power supply circuit open (IG1 or IG2)
C, D
X

*1  :C: CMDTC self test, D: ODDTC self test
*2  :With dual type climate control unit
*3  :With single type climate control unit