DTC P0616:23 [START STOP UNIT]
id0902p6022400
Description |
Circuit malfunction on downstream side of starter relay |
---|---|
Detection condition
|
• Start stop unit detects a short to ground in the starter relay downstream circuit continuously for 0.5 s or more for a continuous 5 times.
|
Fail-safe function
|
Not applicable
|
Possible cause
|
• DTCs are stored in the PCM.
• Start stop unit connector or terminal malfunction
• PCM connector or terminal malfunction
• Short to ground in wiring harness between the following terminals:
• PCM malfunction
• Start stop unit malfunction
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY PCM DTCs
• Retrieve the PCM DTCs using the M-MDS.
• Are any DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [SKYACTIV-D 1.5].)
(See DTC TABLE [SKYACTIV-D 2.2].)
(See DTC TABLE [MZR 1.6].)
|
No
|
Go to the next step.
|
||
2
|
INSPECT START STOP UNIT CONNECTOR CONDITION
• Switch the ignition off.
• Disconnect the negative battery cable.
• Disconnect the start stop unit connector.
• Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
• Is the connector normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the connector, then go to Step 6.
|
||
3
|
INSPECT PCM CONNECTOR CONDITION
• Disconnect the PCM connector.
• Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
• Is the connector normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the connector, then go to Step 6.
|
||
4
|
INSPECT FOR SHORT TO GROUND IN DOWNSTREAM SIDE OF STARTER RELAY CIRCUIT
• Verify that the start stop unit and PCM connectors are disconnected.
• Inspect for continuity between start stop unit terminal 1D (wiring harness-side) and body ground.
• Is there continuity?
|
Yes
|
Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
• Start stop unit terminal 1D—PCM terminal 2AZ (SKYACTIV-G 1.5, SKYACTIV-G 2.0, SKYACTIV-G 2.5)
• Start stop unit terminal 1D—PCM terminal 2BF (SKYACTIV-D 1.5, SKYACTIV-D 2.2)
• Start stop unit terminal 1D—PCM terminal 1F (MZR 1.6)
If there is a common connector:
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
• Repair or replace the malfunctioning part.
If there is no common connector:
• Repair or replace the wiring harness which has a short to ground.
Go to Step 6.
|
No
|
Go to the next step.
|
||
5
|
PERFORM DTC INSPECTION AND VERIFY PCM MALFUNCTION
• Always reconnect all disconnected connectors.
• Reconnect the negative battery cable.
• Clear the DTC for the start stop unit using the M-MDS.
• With the programmed remote transmitter in the vehicle, switch the ignition ON (engine off).
• Perform the following work 5 times or more.
• Retrieve the start stop unit DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Replace the PCM, then go to the next step.
|
No
|
Go to Step 7.
|
||
6
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Always reconnect all disconnected connectors.
• Reconnect the negative battery cable.
• Clear the DTC for the start stop unit using the M-MDS.
• With the programmed remote transmitter in the vehicle, switch the ignition ON (engine off).
• Perform the following work 5 times or more.
• Retrieve the start stop unit DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the start stop unit.
Go to the next step.
|
No
|
Go to the next step.
|
||
7
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [START STOP UNIT].)
|
No
|