DETERMINING SHORT TO GROUND LOCATION (HS-CAN) [SKYACTIV-D 1.5]
id100218000600
System Wiring Diagram
|
Determination Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT FOR SHORT TO GROUND BETWEEN FRONT BODY CONTROL MODULE (FBCM) AND INSTRUMENT CLUSTER
• Disconnect the negative battery cable.
• Disconnect connector 2 which has front body control module (FBCM) terminals 2K and 2I.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to Step 13.
|
No
|
Go to the next step.
|
||
2
|
INSPECT CAN LINE IN FRONT BODY CONTROL MODULE (FBCM) FOR SHORT TO GROUND
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Replace the front body control module (FBCM) because there is a short to ground in the front body control module (FBCM).
|
No
|
Go to the next step.
|
||
3
|
INSPECT FOR SHORT TO GROUND BETWEEN DSC HU/CM AND FRONT BODY CONTROL MODULE (FBCM)
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
• Go to Step 5.(ATX)
• Go to Step 6.(MTX)
|
||
4
|
INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
• Disconnect the DSC HU/CM connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the DSC HU/CM and front body control module (FBCM) because the wiring harness is shorted to ground.
|
No
|
Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM.
|
||
5
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-32 AND FRONT BODY CONTROL MODULE (FBCM)
• Connect connector 2 which has front body control module (FBCM) terminals 2K and 2I.
• Disconnect connector C-32.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between connector C-32 and front body control module (FBCM) because the wiring harness is shorted to ground.
|
No
|
Go to Step 8.
|
||
6
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-01 AND FRONT BODY CONTROL MODULE (FBCM)
• Connect connector 2 which has front body control module (FBCM) terminals 2K and 2I.
• Disconnect connector C-01.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between connector C-01 and front body control module (FBCM) because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
7
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-32 AND CONNECTOR C-01
• Disconnect connector C-32.
• Connect connector C-01.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between connector C-32 and connector C-01 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
8
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-32 AND AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 10.
|
||
9
|
INSPECT CAN LINE IN AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE FOR SHORT TO GROUND
• Disconnect the AFS control module / auto leveling control module connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the AFS control module / auto leveling control module and connector C-32 because the wiring harness is shorted to ground.
|
No
|
Replace the AFS control module / auto leveling control module because there is a short to ground in the AFS control module / auto leveling control module.
|
||
10
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-32 AND TCM
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 38.
|
||
11
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-01 AND TCM
• Disconnect connector C-01.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness between connector C-32 and connector C-01 because the wiring harness is shorted to ground.
|
||
12
|
INSPECT CAN LINE IN TCM FOR SHORT TO GROUND
• Disconnect the TCM connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the TCM and connector C-01 because the wiring harness is shorted to ground.
|
No
|
Replace the TCM because there is a short to ground in the TCM.
|
||
13
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-03 AND INSTRUMENT CLUSTER
• Disconnect connector C-03.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness between connector C-03 and front body control module (FBCM) because the wiring harness is shorted to ground.
|
||
14
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-12 AND INSTRUMENT CLUSTER
• Disconnect connector C-12.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to Step 21.
|
No
|
Go to the next step.
|
||
15
|
INSPECT FOR SHORT TO GROUND BETWEEN LASER SENSOR / FORWARD SENSING CAMERA (FSC) AND CONNECTOR C-12
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness between connector C-03 and connector C-12 because the wiring harness is shorted to ground.
|
||
16
|
INSPECT FOR SHORT TO GROUND BETWEEN LASER SENSOR AND CONNECTOR C-42
• Disconnect connector C-42.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 18.
|
||
17
|
INSPECT CAN LINE IN LASER SENSOR FOR SHORT TO GROUND
• Disconnect the laser sensor connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the laser sensor and connector C-42 because the wiring harness is shorted to ground.
|
No
|
Replace the laser sensor because there is a short to ground in the laser sensor.
|
||
18
|
INSPECT FOR SHORT TO GROUND BETWEEN FORWARD SENSING CAMERA (FSC) AND CONNECTOR C-42
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness between connector C-12 and connector C-42 because the wiring harness is shorted to ground.
|
||
19
|
INSPECT FOR SHORT TO GROUND BETWEEN FORWARD SENSING CAMERA (FSC) AND CONNECTOR C-27
• Disconnect connector C-27.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness between connector C-42 and connector C-27 because the wiring harness is shorted to ground.
|
||
20
|
INSPECT CAN LINE IN FORWARD SENSING CAMERA (FSC) FOR SHORT TO GROUND
• Disconnect the forward sensing camera (FSC) connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the forward sensing camera (FSC) and connector C-27 because the wiring harness is shorted to ground.
|
No
|
Replace the forward sensing camera (FSC) because there is a short to ground in the forward sensing camera (FSC).
|
||
21
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-33 AND DLC-2
• Disconnect connector C-33.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between DLC-2 and connector C-33 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
22
|
INSPECT FOR SHORT TO GROUND BETWEEN START STOP UNIT AND CONNECTOR C-33
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 24.
|
||
23
|
INSPECT CAN LINE IN START STOP UNIT FOR SHORT TO GROUND
• Disconnect the start stop unit connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the start stop unit and connector C-33 because the wiring harness is shorted to ground.
|
No
|
Replace the start stop unit because there is a short to ground in the start stop unit.
|
||
24
|
INSPECT FOR SHORT TO GROUND BETWEEN EPS CONTROL MODULE AND CONNECTOR C-33
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 26.
|
||
25
|
INSPECT CAN LINE IN EPS CONTROL MODULE FOR SHORT TO GROUND
• Disconnect the EPS control module connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the EPS control module and connector C-33 because the wiring harness is shorted to ground.
|
No
|
Replace the EPS control module because there is a short to ground in the EPS control module.
|
||
26
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-34 AND INSTRUMENT CLUSTER
• Disconnect connector C-34.
• Connect connector C-33.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Replace the JB No.2 because there is a short to ground in the JB No.2.
|
No
|
Go to the next step.
|
||
27
|
INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTOR C-34
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 29.
|
||
28
|
INSPECT CAN LINE IN SAS CONTROL MODULE FOR SHORT TO GROUND
• Disconnect the SAS control module connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the SAS control module and connector C-34 because the wiring harness is shorted to ground.
|
No
|
Replace the SAS control module because there is a short to ground in the SAS control module.
|
||
29
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTIVITY MASTER UNIT (CMU) AND CONNECTOR C-34
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 31.
|
||
30
|
INSPECT CAN LINE IN CONNECTIVITY MASTER UNIT (CMU) FOR SHORT TO GROUND
• Disconnect the connectivity master unit (CMU) connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connectivity master unit (CMU) and connector C-34 because the wiring harness is shorted to ground.
|
No
|
Replace the connectivity master unit (CMU) because there is a short to ground in the connectivity master unit (CMU).
|
||
31
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-09 AND INSTRUMENT CLUSTER
• Disconnect connector C-09.
• Connect connector C-34.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connector C-34 and connector C-09 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
32
|
INSPECT FOR SHORT TO GROUND BETWEEN AUDIO AMPLIFIER/VEHICLE CONTROL MODULE (V/C-MODULE) AND CONNECTOR C-09
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 37.
|
||
33
|
INSPECT FOR SHORT TO GROUND BETWEEN AUDIO AMPLIFIER AND CONNECTOR C-40
• Disconnect connector C-40.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 35.
|
||
34
|
INSPECT CAN LINE IN AUDIO AMPLIFIER FOR SHORT TO GROUND
• Disconnect the audio amplifier connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the audio amplifier and connector C-40 because the wiring harness is shorted to ground.
|
No
|
Replace the audio amplifier because there is a short to ground in the audio amplifier.
|
||
35
|
INSPECT FOR SHORT TO GROUND BETWEEN VEHICLE CONTROL MODULE (V/C-MODULE) AND CONNECTOR C-40
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness between connector C-40 and connector C-09 because the wiring harness is shorted to ground.
|
||
36
|
INSPECT CAN LINE IN VEHICLE CONTROL MODULE (V/C-MODULE) FOR SHORT TO GROUND
• Disconnect the vehicle control module (V/C-module) connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the vehicle control module (V/C-module) and connector C-40 because the wiring harness is shorted to ground.
|
No
|
Replace the vehicle control module (V/C-module) because there is a short to ground in the vehicle control module (V/C-module).
|
||
37
|
INSPECT CAN LINE IN INSTRUMENT CLUSTER FOR SHORT TO GROUND
• Disconnect the instrument cluster connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the instrument cluster and connector C-09 because the wiring harness is shorted to ground.
|
No
|
Replace the instrument cluster because there is a short to ground in the instrument cluster.
|
||
38
|
INSPECT CAN LINE IN PCM FOR SHORT TO GROUND
• Disconnect the PCM connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the PCM and connector C-32 because the wiring harness is shorted to ground.
|
No
|
Replace the PCM because there is a short to ground in the PCM.
|