DETERMINING SHORT TO GROUND LOCATION (HS-CAN) [SKYACTIV-D 1.5]


id100218000600

Caution
•  Perform the following malfunction diagnosis only when it is diagnosed with a short to ground by CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW. (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [SKYACTIV-D 1.5].)

System Wiring Diagram

am3zzw00016256

Determination Procedure

Caution
•  When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.
•  When inspecting the DLC-2, touch it with a paper clip or similar thin pin without directly inserting a tester into the terminals.

Step

Inspection

Action

1
INSPECT FOR SHORT TO GROUND BETWEEN FRONT BODY CONTROL MODULE (FBCM) AND INSTRUMENT CLUSTER
•  Disconnect the negative battery cable.
•  Disconnect connector 2 which has front body control module (FBCM) terminals 2K and 2I.
•  Inspect for continuity at the following terminals:
―  Between DLC-2 terminal F and body ground
―  Between DLC-2 terminal E and body ground
•  Is there continuity?
Yes
Go to Step 13.
No
Go to the next step.
2
INSPECT CAN LINE IN FRONT BODY CONTROL MODULE (FBCM) FOR SHORT TO GROUND
•  Inspect for continuity at the following terminals:
―  Between front body control module (FBCM) terminal 2K and body ground
―  Between front body control module (FBCM) terminal 2I and body ground
•  Is there continuity?
Yes
Replace the front body control module (FBCM) because there is a short to ground in the front body control module (FBCM).
No
Go to the next step.
3
INSPECT FOR SHORT TO GROUND BETWEEN DSC HU/CM AND FRONT BODY CONTROL MODULE (FBCM)
•  Inspect for continuity at the following terminals:
―  Between DSC HU/CM terminal AF and body ground
―  Between DSC HU/CM terminal AC and body ground
•  Is there continuity?
Yes
Go to the next step.
No
•  Go to Step 5.(ATX)
•  Go to Step 6.(MTX)
4
INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
•  Disconnect the DSC HU/CM connector.
•  Inspect for continuity at the following terminals:
―  Between DSC HU/CM terminal AF (wiring harness side) and body ground
―  Between DSC HU/CM terminal AC (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the DSC HU/CM and front body control module (FBCM) because the wiring harness is shorted to ground.
No
Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM.
5
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-32 AND FRONT BODY CONTROL MODULE (FBCM)
•  Connect connector 2 which has front body control module (FBCM) terminals 2K and 2I.
•  Disconnect connector C-32.
•  Inspect for continuity at the following terminals:
―  Between DLC-2 terminal F and body ground
―  Between DLC-2 terminal E and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between connector C-32 and front body control module (FBCM) because the wiring harness is shorted to ground.
No
Go to Step 8.
6
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-01 AND FRONT BODY CONTROL MODULE (FBCM)
•  Connect connector 2 which has front body control module (FBCM) terminals 2K and 2I.
•  Disconnect connector C-01.
•  Inspect for continuity at the following terminals:
―  Between DLC-2 terminal F and body ground
―  Between DLC-2 terminal E and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between connector C-01 and front body control module (FBCM) because the wiring harness is shorted to ground.
No
Go to the next step.
7
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-32 AND CONNECTOR C-01
•  Disconnect connector C-32.
•  Connect connector C-01.
•  Inspect for continuity at the following terminals:
―  Between DLC-2 terminal F and body ground
―  Between DLC-2 terminal E and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between connector C-32 and connector C-01 because the wiring harness is shorted to ground.
No
Go to the next step.
8
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-32 AND AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE
•  Inspect for continuity at the following terminals:
―  Between AFS control module / auto leveling control module terminal A and body ground
―  Between AFS control module / auto leveling control module terminal B and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Go to Step 10.
9
INSPECT CAN LINE IN AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE FOR SHORT TO GROUND
•  Disconnect the AFS control module / auto leveling control module connector.
•  Inspect for continuity at the following terminals:
―  Between AFS control module / auto leveling control module terminal A (wiring harness side) and body ground
―  Between AFS control module / auto leveling control module terminal B (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the AFS control module / auto leveling control module and connector C-32 because the wiring harness is shorted to ground.
No
Replace the AFS control module / auto leveling control module because there is a short to ground in the AFS control module / auto leveling control module.
10
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-32 AND TCM
•  Inspect for continuity at the following terminals:
―  Between TCM terminal E and body ground
―  Between TCM terminal F and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Go to Step 38.
11
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-01 AND TCM
•  Disconnect connector C-01.
•  Inspect for continuity at the following terminals:
―  Between TCM terminal E and body ground
―  Between TCM terminal F and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Repair or replace the wiring harness between connector C-32 and connector C-01 because the wiring harness is shorted to ground.
12
INSPECT CAN LINE IN TCM FOR SHORT TO GROUND
•  Disconnect the TCM connector.
•  Inspect for continuity at the following terminals:
―  Between TCM terminal E (wiring harness side) and body ground
―  Between TCM terminal F (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the TCM and connector C-01 because the wiring harness is shorted to ground.
No
Replace the TCM because there is a short to ground in the TCM.
13
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-03 AND INSTRUMENT CLUSTER
•  Disconnect connector C-03.
•  Inspect for continuity at the following terminals:
―  Between DLC-2 terminal F and body ground
―  Between DLC-2 terminal E and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Repair or replace the wiring harness between connector C-03 and front body control module (FBCM) because the wiring harness is shorted to ground.
14
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-12 AND INSTRUMENT CLUSTER
•  Disconnect connector C-12.
•  Inspect for continuity at the following terminals:
―  Between DLC-2 terminal F and body ground
―  Between DLC-2 terminal E and body ground
•  Is there continuity?
Yes
Go to Step 21.
No
Go to the next step.
15
INSPECT FOR SHORT TO GROUND BETWEEN LASER SENSOR / FORWARD SENSING CAMERA (FSC) AND CONNECTOR C-12
•  Inspect for continuity at the following terminals:
―  Between laser sensor terminal D and body ground (with smart city brake support (SCBS))
―  Between laser sensor terminal C and body ground (with smart city brake support (SCBS))
―  Between forward sensing camera (FSC) terminal E and body ground (with forward sensing camera (FSC))
―  Between forward sensing camera (FSC) terminal C and body ground (with forward sensing camera (FSC))
•  Is there continuity?
Yes
Go to the next step.
No
Repair or replace the wiring harness between connector C-03 and connector C-12 because the wiring harness is shorted to ground.
16
INSPECT FOR SHORT TO GROUND BETWEEN LASER SENSOR AND CONNECTOR C-42
•  Disconnect connector C-42.
•  Inspect for continuity at the following terminals:
―  Between laser sensor terminal D and body ground
―  Between laser sensor terminal C and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Go to Step 18.
17
INSPECT CAN LINE IN LASER SENSOR FOR SHORT TO GROUND
•  Disconnect the laser sensor connector.
•  Inspect for continuity at the following terminals:
―  Between laser sensor terminal D (wiring harness side) and body ground
―  Between laser sensor terminal C (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the laser sensor and connector C-42 because the wiring harness is shorted to ground.
No
Replace the laser sensor because there is a short to ground in the laser sensor.
18
INSPECT FOR SHORT TO GROUND BETWEEN FORWARD SENSING CAMERA (FSC) AND CONNECTOR C-42
•  Inspect for continuity at the following terminals:
―  Between forward sensing camera (FSC) terminal E and body ground
―  Between forward sensing camera (FSC) terminal C and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Repair or replace the wiring harness between connector C-12 and connector C-42 because the wiring harness is shorted to ground.
19
INSPECT FOR SHORT TO GROUND BETWEEN FORWARD SENSING CAMERA (FSC) AND CONNECTOR C-27
•  Disconnect connector C-27.
•  Inspect for continuity at the following terminals:
―  Between forward sensing camera (FSC) terminal E and body ground
―  Between forward sensing camera (FSC) terminal C and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Repair or replace the wiring harness between connector C-42 and connector C-27 because the wiring harness is shorted to ground.
20
INSPECT CAN LINE IN FORWARD SENSING CAMERA (FSC) FOR SHORT TO GROUND
•  Disconnect the forward sensing camera (FSC) connector.
•  Inspect for continuity at the following terminals:
―  Between forward sensing camera (FSC) terminal E (wiring harness side) and body ground
―  Between forward sensing camera (FSC) terminal C (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the forward sensing camera (FSC) and connector C-27 because the wiring harness is shorted to ground.
No
Replace the forward sensing camera (FSC) because there is a short to ground in the forward sensing camera (FSC).
21
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-33 AND DLC-2
•  Disconnect connector C-33.
•  Inspect for continuity at the following terminals:
―  Between DLC-2 terminal F and body ground
―  Between DLC-2 terminal E and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between DLC-2 and connector C-33 because the wiring harness is shorted to ground.
No
Go to the next step.
22
INSPECT FOR SHORT TO GROUND BETWEEN START STOP UNIT AND CONNECTOR C-33
•  Inspect for continuity at the following terminals:
―  Between start stop unit terminal 2M and body ground
―  Between start stop unit terminal 2O and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Go to Step 24.
23
INSPECT CAN LINE IN START STOP UNIT FOR SHORT TO GROUND
•  Disconnect the start stop unit connector.
•  Inspect for continuity at the following terminals:
―  Between start stop unit terminal 2M (wiring harness side) and body ground
―  Between start stop unit terminal 2O (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the start stop unit and connector C-33 because the wiring harness is shorted to ground.
No
Replace the start stop unit because there is a short to ground in the start stop unit.
24
INSPECT FOR SHORT TO GROUND BETWEEN EPS CONTROL MODULE AND CONNECTOR C-33
•  Inspect for continuity at the following terminals:
―  Between EPS control module terminal 2B and body ground
―  Between EPS control module terminal 2D and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Go to Step 26.
25
INSPECT CAN LINE IN EPS CONTROL MODULE FOR SHORT TO GROUND
•  Disconnect the EPS control module connector.
•  Inspect for continuity at the following terminals:
―  Between EPS control module terminal 2B (wiring harness side) and body ground
―  Between EPS control module terminal 2D (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the EPS control module and connector C-33 because the wiring harness is shorted to ground.
No
Replace the EPS control module because there is a short to ground in the EPS control module.
26
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-34 AND INSTRUMENT CLUSTER
•  Disconnect connector C-34.
•  Connect connector C-33.
•  Inspect for continuity at the following terminals:
―  Between DLC-2 terminal F and body ground
―  Between DLC-2 terminal E and body ground
•  Is there continuity?
Yes
Replace the JB No.2 because there is a short to ground in the JB No.2.
No
Go to the next step.
27
INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTOR C-34
•  Inspect for continuity at the following terminals:
―  Between SAS control module terminal 3K and body ground. (with connector 22-pin type)
―  Between SAS control module terminal 3L and body ground. (with connector 22-pin type)
―  Between SAS control module terminal 3B and body ground. (with connector 32-pin type)
―  Between SAS control module terminal 3C and body ground. (with connector 32-pin type)
•  Is there continuity?
Yes
Go to the next step.
No
Go to Step 29.
28
INSPECT CAN LINE IN SAS CONTROL MODULE FOR SHORT TO GROUND
•  Disconnect the SAS control module connector.
•  Inspect for continuity at the following terminals:
―  Between SAS control module terminal 3K (wiring harness side) and body ground. (with connector 22-pin type)
―  Between SAS control module terminal 3L (wiring harness side) and body ground. (with connector 22-pin type)
―  Between SAS control module terminal 3B (wiring harness side) and body ground. (with connector 32-pin type)
―  Between SAS control module terminal 3C (wiring harness side) and body ground. (with connector 32-pin type)
•  Is there continuity?
Yes
Repair or replace the wiring harness between the SAS control module and connector C-34 because the wiring harness is shorted to ground.
No
Replace the SAS control module because there is a short to ground in the SAS control module.
29
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTIVITY MASTER UNIT (CMU) AND CONNECTOR C-34
•  Inspect for continuity at the following terminals:
―  Between connectivity master unit (CMU) terminal 2E and body ground
―  Between connectivity master unit (CMU) terminal 2F and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Go to Step 31.
30
INSPECT CAN LINE IN CONNECTIVITY MASTER UNIT (CMU) FOR SHORT TO GROUND
•  Disconnect the connectivity master unit (CMU) connector.
•  Inspect for continuity at the following terminals:
―  Between connectivity master unit (CMU) terminal 2E (wiring harness side) and body ground
―  Between connectivity master unit (CMU) terminal 2F (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the connectivity master unit (CMU) and connector C-34 because the wiring harness is shorted to ground.
No
Replace the connectivity master unit (CMU) because there is a short to ground in the connectivity master unit (CMU).
31
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-09 AND INSTRUMENT CLUSTER
•  Disconnect connector C-09.
•  Connect connector C-34.
•  Inspect for continuity at the following terminals:
―  Between DLC-2 terminal F and body ground
―  Between DLC-2 terminal E and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the connector C-34 and connector C-09 because the wiring harness is shorted to ground.
No
Go to the next step.
32
INSPECT FOR SHORT TO GROUND BETWEEN AUDIO AMPLIFIER/VEHICLE CONTROL MODULE (V/C-MODULE) AND CONNECTOR C-09
•  Inspect for continuity at the following terminals:
―  Between audio amplifier terminal 2L and body ground (with Bose® type audio)
―  Between audio amplifier terminal 2N and body ground (with Bose® type audio)
―  Between vehicle control module (V/C-module) terminal S and body ground (with mazda radar cruise control (MRCC) system)
―  Between vehicle control module (V/C-module) terminal U and body ground (with mazda radar cruise control (MRCC) system)
•  Is there continuity?
Yes
Go to the next step.
No
Go to Step 37.
33
INSPECT FOR SHORT TO GROUND BETWEEN AUDIO AMPLIFIER AND CONNECTOR C-40
•  Disconnect connector C-40.
•  Inspect for continuity at the following terminals:
―  Between audio amplifier terminal 2L and body ground
―  Between audio amplifier terminal 2N and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Go to Step 35.
34
INSPECT CAN LINE IN AUDIO AMPLIFIER FOR SHORT TO GROUND
•  Disconnect the audio amplifier connector.
•  Inspect for continuity at the following terminals:
―  Between audio amplifier terminal 2L (wiring harness side) and body ground
―  Between audio amplifier terminal 2N (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the audio amplifier and connector C-40 because the wiring harness is shorted to ground.
No
Replace the audio amplifier because there is a short to ground in the audio amplifier.
35
INSPECT FOR SHORT TO GROUND BETWEEN VEHICLE CONTROL MODULE (V/C-MODULE) AND CONNECTOR C-40
•  Inspect for continuity at the following terminals:
―  Between vehicle control module (V/C-module) terminal S and body ground
―  Between vehicle control module (V/C-module) terminal U and body ground
•  Is there continuity?
Yes
Go to the next step.
No
Repair or replace the wiring harness between connector C-40 and connector C-09 because the wiring harness is shorted to ground.
36
INSPECT CAN LINE IN VEHICLE CONTROL MODULE (V/C-MODULE) FOR SHORT TO GROUND
•  Disconnect the vehicle control module (V/C-module) connector.
•  Inspect for continuity at the following terminals:
―  Between vehicle control module (V/C-module) terminal S (wiring harness side) and body ground
―  Between vehicle control module (V/C-module) terminal U (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the vehicle control module (V/C-module) and connector C-40 because the wiring harness is shorted to ground.
No
Replace the vehicle control module (V/C-module) because there is a short to ground in the vehicle control module (V/C-module).
37
INSPECT CAN LINE IN INSTRUMENT CLUSTER FOR SHORT TO GROUND
•  Disconnect the instrument cluster connector.
•  Inspect for continuity at the following terminals:
―  Between instrument cluster terminal B (wiring harness side) and body ground
―  Between instrument cluster terminal D (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the instrument cluster and connector C-09 because the wiring harness is shorted to ground.
No
Replace the instrument cluster because there is a short to ground in the instrument cluster.
38
INSPECT CAN LINE IN PCM FOR SHORT TO GROUND
•  Disconnect the PCM connector.
•  Inspect for continuity at the following terminals:
―  Between PCM terminal 2C (wiring harness side) and body ground
―  Between PCM terminal 2D (wiring harness side) and body ground
•  Is there continuity?
Yes
Repair or replace the wiring harness between the PCM and connector C-32 because the wiring harness is shorted to ground.
No
Replace the PCM because there is a short to ground in the PCM.